【版權(quan)聲明】:我們尊重原創(chuang),也注(zhu)重分享(xiang)。有(you)部(bu)分內(nei)(nei)容來(lai)自互聯網(wang),版權(quan)歸(gui)原作者(zhe)(zhe)所有(you),僅供(gong)學習參考之用(yong),禁(jin)止(zhi)用(yong)于商業(ye)用(yong)途,本平臺對(dui)轉載、分享(xiang)的(de)(de)內(nei)(nei)容、陳述(shu)、觀(guan)點判斷保(bao)持中(zhong)立(li),不對(dui)所包含內(nei)(nei)容的(de)(de)準(zhun)確(que)性、可靠性或完(wan)善性提供(gong)任(ren)何(he)明示或暗示的(de)(de)保(bao)證,僅供(gong)讀者(zhe)(zhe)參考,如無意中(zhong)侵(qin)犯(fan)了哪個(ge)媒體、公司 、企(qi)業(ye)或個(ge)人等的(de)(de)知(zhi)識產權(quan),請(qing)聯系(xi)刪(shan)除。謝謝!
|
一文了解冷卻水處理系統運行和設計工業循環冷卻(que)水(shui)(shui)系統(tong)在運行過(guo)程中(zhong)(zhong)(zhong),由(you)于水(shui)(shui)的蒸發和(he)風的損失,循環水(shui)(shui)不(bu)斷集中(zhong)(zhong)(zhong)。系統(tong)中(zhong)(zhong)(zhong)所含(han)的鹽過(guo)多,陽離子和(he)陽離子數量增加(jia),ph值(zhi)變化顯著,導致水(shui)(shui)質(zhi)惡化,循環水(shui)(shui)溫度(du)升高。ph值(zhi)和(he)養(yang)分有利于微生物(wu)的繁殖。冷卻(que)塔上(shang)充(chong)足的陽光是藻類(lei)生長的理想(xiang)場所。以及(ji)規模控(kong)制(zhi)(zhi)和(he)腐蝕控(kong)制(zhi)(zhi)、微生物(wu)控(kong)制(zhi)(zhi)等,不(bu)可避免地需要循環用水(shui)(shui)處理。 循環(huan)水運行中(zhong)的(de)主要問題 (1)結垢:由于循環水在冷(leng)卻過程中不(bu)斷蒸(zheng)發(fa),水中的鹽(yan)濃(nong)度(du)不(bu)斷增加,超過了(le)(le)某些鹽(yan)和沉淀物的溶解度(du)。常(chang)見的氧(yang)化皮(pi)有(you)碳酸鈣、磷酸鈣、硅酸鎂等。鱗片(pian)質地致(zhi)密,大(da)大(da)降(jiang)低了(le)(le)傳熱效率。刻度(du)厚度(du)為(wei)0.6 mm時,傳熱系數降(jiang)低了(le)(le)20%。 (二)污(wu)(wu)垢(gou):污(wu)(wu)垢(gou)主要由水(shui)中有(you)機物(wu)(wu)、微生物(wu)(wu)菌落和分泌物(wu)(wu)、淤泥、粉(fen)塵等(deng)組(zu)成(cheng)。土(tu)質(zhi)質(zhi)地柔軟(ruan),既降(jiang)低了(le)傳熱效率,又會導致(zhi)土(tu)質(zhi)下的(de)腐蝕,縮短(duan)了(le)設備的(de)使用壽命。 (3)腐(fu)(fu)蝕:循環(huan)水(shui)對熱(re)(re)交(jiao)(jiao)換設備的(de)(de)腐(fu)(fu)蝕,主要是電(dian)偶腐(fu)(fu)蝕,由(you)設備制造缺陷,水(shui)中充(chong)足(zu)的(de)(de)氧氣,水(shui)中的(de)(de)腐(fu)(fu)蝕性離子(Cl-,Fe2 +,Cu2 +)和微(wei)生物分泌的(de)(de)粘液引起的(de)(de)腐(fu)(fu)蝕其他因素,腐(fu)(fu)蝕的(de)(de)后果非常嚴(yan)重,即使(shi)熱(re)(re)交(jiao)(jiao)換器,水(shui)管道設備報廢,也無需在很短的(de)(de)時間內控制。 (4)微(wei)生(sheng)(sheng)物粘液:由于循環水(shui)溶(rong)解(jie)氧(yang)充(chong)足,溫度適宜,營(ying)養豐富,非常(chang)適合微(wei)生(sheng)(sheng)物生(sheng)(sheng)長繁殖。如果不及時控(kong)制,將很快導致(zhi)水(shui)質惡化、異味(wei)、發黑、冷(leng)卻塔結(jie)垢大量或堵塞(sai),大大降低冷(leng)卻散熱(re)效果,加劇設(she)備腐蝕(shi)。因此,在循環水(shui)處理中必須控(kong)制微(wei)生(sheng)(sheng)物的繁殖。 微生物(wu)危害 循環(huan)冷(leng)(leng)卻水中的(de)微(wei)生(sheng)(sheng)(sheng)物(wu)有兩(liang)種來源。首先是(shi)冷(leng)(leng)卻塔需(xu)要在(zai)蒸發過程中引入(ru)(ru)大(da)量的(de)空(kong)氣,微(wei)生(sheng)(sheng)(sheng)物(wu)也會(hui)隨空(kong)氣帶入(ru)(ru)冷(leng)(leng)卻水,其次,加入(ru)(ru)冷(leng)(leng)卻水系(xi)統的(de)水或多或少會(hui)產(chan)生(sheng)(sheng)(sheng)微(wei)生(sheng)(sheng)(sheng)物(wu)。這些微(wei)生(sheng)(sheng)(sheng)物(wu)也與補充水一起進入(ru)(ru)冷(leng)(leng)卻水系(xi)統。 在(zai)陽光照(zhao)射(she)下(xia),藻類(lei)將與水(shui)(shui)中(zhong)(zhong)的(de)(de)二(er)氧(yang)化碳(tan)(tan)和碳(tan)(tan)酸氫鹽等碳(tan)(tan)源配合,吸收碳(tan)(tan)作為營養物(wu)質釋放(fang)氧(yang)氣。因此,當藻類(lei)繁殖(zhi)(zhi)時,它會(hui)增(zeng)加水(shui)(shui)中(zhong)(zhong)的(de)(de)溶解氧(yang)含量(liang)(liang),這對氧(yang)氣有益(yi)。去極(ji)化過程,因此加速了腐(fu)蝕過程。循環(huan)(huan)(huan)水(shui)(shui)系(xi)統中(zhong)(zhong)微(wei)生物(wu)的(de)(de)大規模(mo)繁殖(zhi)(zhi)會(hui)使(shi)循環(huan)(huan)(huan)水(shui)(shui)的(de)(de)顏(yan)色變黑,造(zao)成惡臭并污染(ran)環(huan)(huan)(huan)境(jing)。同時,形成大量(liang)(liang)的(de)(de)粘(zhan)液以降低冷(leng)卻塔的(de)(de)冷(leng)卻效(xiao)率,并且木材劣化和腐(fu)爛。 在換熱器中沉積的(de)污泥降低了(le)(le)換熱效(xiao)率,增加了(le)(le)水頭損失。沉積在金屬表面的(de)污泥在水垢(gou)下會引(yin)起(qi)嚴重的(de)腐蝕(shi)(shi)。同時,還(huan)分離了(le)(le)緩(huan)蝕(shi)(shi)阻垢(gou)劑對金屬的(de)影響,使緩(huan)蝕(shi)(shi)阻垢(gou)劑不能發揮應有(you)的(de)緩(huan)蝕(shi)(shi)阻垢(gou)效(xiao)果。 除了加速(su)微生(sheng)物(wu)粘液的腐(fu)蝕外,一些(xie)細菌在代謝過程中,生(sheng)物(wu)分泌(mi)物(wu)也會直(zhi)接腐(fu)蝕金屬。這(zhe)些(xie)問題導(dao)致循環(huan)水系統長(chang)期運行不(bu)安(an)全,影響生(sheng)產,造成(cheng)嚴重的經(jing)濟(ji)損失。因此,微生(sheng)物(wu)對冷(leng)卻水系統造成(cheng)的危(wei)害(hai)與(yu)規模和腐(fu)蝕造成(cheng)的危(wei)害(hai)一樣嚴重。甚至可以(yi)說,這(zhe)三者是(shi)第一個控制微生(sheng)物(wu)危(wei)害(hai)的。 循環水中微生物的運動可通(tong)過以下化學分析項目測量: (1)氯(lv)(lv)(lv)化消毒余氯(lv)(lv)(lv)(游離氯(lv)(lv)(lv))時(shi),應注意余氯(lv)(lv)(lv)出現的(de)時(shi)間和余氯(lv)(lv)(lv)的(de)量,因為當(dang)微生物繁殖嚴重時(shi),循環水中氯(lv)(lv)(lv)的(de)消耗量會大(da)大(da)增加。 (2)氨(an)(an)(an)循環(huan)水一般不(bu)含(han)(han)氨(an)(an)(an),但由于過程中(zhong)氨(an)(an)(an)的泄漏(lou)介質或吸入(ru)空氣中(zhong)的氨(an)(an)(an),水中(zhong)也會出現氨(an)(an)(an)。在這個時候,不(bu)能(neng)掉(diao)以輕心。除了積極尋(xun)找氨(an)(an)(an)的漏(lou)點外,還要(yao)注意水中(zhong)是否含(han)(han)有(you)亞硝酸鹽(yan)。水中(zhong)的氨(an)(an)(an)含(han)(han)量最(zui)好控制(zhi)在10毫(hao)克/升以下。 (3)NO2-當水中(zhong)存在氨(an)和亞硝酸鹽時,據說水中(zhong)的(de)(de)亞硝酸鹽細菌將氨(an)轉化為亞硝酸鹽。此時,循環水系統中(zhong)的(de)(de)氯(lv)將變得非(fei)常困難(nan)并且氯(lv)消(xiao)耗將增加。殘(can)留的(de)(de)氯(lv)難(nan)以(yi)達到指數,并且水中(zhong)的(de)(de)NO 2含量(liang)優選(xuan)控制在小于1mg / l。 (4)當COD水(shui)中微生物(wu)繁(fan)殖嚴重時,COD增(zeng)加。由于細(xi)菌分泌的粘液增(zeng)加了(le)水(shui)中有機物(wu)的含(han)量,通過(guo)對COD的分析可以觀(guan)察(cha)到水(shui)中微生物(wu)的變化趨勢。在正常情況下(xia),水(shui)中的COD比5 mg/L(kmno4法(fa))好(hao)。 微生物(wu)(wu)(wu)對循環(huan)水(shui)的(de)危害非(fei)常嚴重。如(ru)果(guo)要(yao)在微生物(wu)(wu)(wu)造成的(de)損害之后(hou)采(cai)取措施,那往往是時間(jian)和時間(jian)的(de)問題(ti),而(er)且(qie)也要(yao)花費大量的(de)殺蟲劑和金錢(qian)。因此,有必要(yao)提(ti)前(qian)對循環(huan)冷卻水(shui)的(de)微生物(wu)(wu)(wu)條件進行全面監(jian)測。 濃(nong)縮倍數(shu) 循(xun)(xun)環水(shui)(shui)濃(nong)度系數是指(zhi)循(xun)(xun)環水(shui)(shui)系統運行期間(jian)由于水(shui)(shui)的(de)蒸發(fa),風失等等而使循(xun)(xun)環水(shui)(shui)連續濃(nong)縮的(de)速率(lv)(與補充水(shui)(shui)相比(bi)),這是衡量(liang)循(xun)(xun)環水(shui)(shui)的(de)重(zhong)要指(zhi)標(biao)。水(shui)(shui)質(zhi)控制(zhi)(zhi)。綜合指(zhi)標(biao)。濃(nong)度比(bi)低,耗水(shui)(shui)量(liang)和污水(shui)(shui)量(liang)大,水(shui)(shui)處(chu)理(li)(li)(li)劑效(xiao)率(lv)不高;高濃(nong)度因(yin)(yin)子可以減少水(shui)(shui)量(liang),節省水(shui)(shui)處(chu)理(li)(li)(li)成(cheng)本;但是,如果濃(nong)度倍數過高,則水(shui)(shui)垢傾向(xiang)會(hui)增(zeng)加。結垢控制(zhi)(zhi)和腐蝕控制(zhi)(zhi)的(de)難度會(hui)增(zeng)加,水(shui)(shui)處(chu)理(li)(li)(li)劑會(hui)失效(xiao),不利于微生物的(de)控制(zhi)(zhi),因(yin)(yin)此循(xun)(xun)環水(shui)(shui)的(de)濃(nong)度應(ying)該(gai)有一個合理(li)(li)(li)的(de)控制(zhi)(zhi)指(zhi)標(biao)。 水垢的形成 在循環水系統中(zhong)(zhong)(zhong),過(guo)飽和(he)水溶性(xing)組(zu)分形(xing)成(cheng)水垢。水中(zhong)(zhong)(zhong)溶解(jie)(jie)著各種(zhong)鹽(yan)(yan)(yan)類,如碳酸(suan)氫(qing)(qing)鹽(yan)(yan)(yan)、碳酸(suan)鹽(yan)(yan)(yan)、氯化物、硅酸(suan)鹽(yan)(yan)(yan)等(deng)。其中(zhong)(zhong)(zhong),鈣(gai)(gai)(HCO 3)2、鎂(HCO 3)2等(deng)溶解(jie)(jie)性(xing)碳酸(suan)氫(qing)(qing)鹽(yan)(yan)(yan)最不穩定(ding),易(yi)分解(jie)(jie)成(cheng)碳酸(suan)鹽(yan)(yan)(yan)。因(yin)此,當冷卻水中(zhong)(zhong)(zhong)溶解(jie)(jie)的碳酸(suan)氫(qing)(qing)鹽(yan)(yan)(yan)較多時(shi),水就通過(guo)傳熱(re)來流動。容(rong)器的表面(mian),特別是(shi)溫度(du)(du)較高(gao)的表面(mian),受熱(re)分解(jie)(jie);當磷酸(suan)鹽(yan)(yan)(yan)和(he)鈣(gai)(gai)離子(zi)溶于(yu)水中(zhong)(zhong)(zhong)時(shi),磷酸(suan)鈣(gai)(gai)也會沉淀;碳酸(suan)鈣(gai)(gai)和(he)Ca3(PO4)2不溶,與普通鹽(yan)(yan)(yan)不同。它們(men)的溶解(jie)(jie)度(du)(du)不隨(sui)溫度(du)(du)的升(sheng)高(gao)而增加,而是(shi)隨(sui)溫度(du)(du)的升(sheng)高(gao)而降低。 因(yin)(yin)此,在熱交(jiao)換(huan)器的傳熱面上,這些(xie)不溶性鹽很容易達到過飽和,在水中結(jie)晶(jing)(jing)。特(te)別是(shi)當流動(dong)速度小或傳熱面粗糙時,這些(xie)結(jie)晶(jing)(jing)沉積(ji)物會(hui)沉積(ji)在傳熱面上,形(xing)成(cheng)常被稱為(wei)鱗片(pian),因(yin)(yin)為(wei)這些(xie)鱗片(pian)晶(jing)(jing)體密(mi)集(ji),相對堅(jian)硬(ying),也被稱為(wei)硬(ying)鱗,常見的鱗片(pian)成(cheng)分(fen)有:碳(tan)酸(suan)鈣(gai)、硫酸(suan)鈣(gai)、磷酸(suan)鈣(gai)、鎂鹽、硅酸(suan)鹽。 循環(huan)水處理技術 根(gen)據企業循環(huan)水系統的特(te)點和技術條件,結合當(dang)地水質特(te)點,選擇適(shi)合企業經營狀(zhuang)況(kuang)的水處理(li)方案,通過(guo)控(kong)制循環(huan)水指標在一定范圍內運行。加藥等措施,不僅(jin)可以確保生產設備的長(chang)周(zhou)期。操作,提高循環(huan)水的利用率(lv)。 一、冷(leng)卻水系統設計程序 安裝1個(ge)冷(leng)卻水泵(beng)和冷(leng)卻塔(ta) 每個(ge)冷(leng)卻(que)(que)塔(ta)應(ying)至少安裝(zhuang)一(yi)個(ge)泵。通(tong)常(chang)應(ying)考慮備用泵進行維(wei)護。通(tong)常(chang),水(shui)(shui)泵和空(kong)調冷(leng)卻(que)(que)水(shui)(shui)系統的(de)單元之間的(de)連(lian)接是(shi)壓(ya)入(ru)式(用于(yu)該單元),并(bing)且(qie)在水(shui)(shui)泵的(de)吸入(ru)部分中僅足夠的(de)壓(ya)頭可以(yi)防止水(shui)(shui)蒸(zheng)發。大多數冷(leng)卻(que)(que)塔(ta)都(dou)是(shi)敞開的(de),并(bing)配有(you)風(feng)扇,以(yi)強制空(kong)氣和冷(leng)卻(que)(que)水(shui)(shui)的(de)對流(liu),以(yi)改善空(kong)氣的(de)冷(leng)卻(que)(que)效(xiao)果。該塔(ta)配有(you)高(gao)密度親水(shui)(shui)填充材料(liao)。常(chang)用的(de)冷(leng)卻(que)(que)塔(ta)是(shi)逆流(liu)式和直式AC型。冷(leng)卻(que)(que)塔(ta)應(ying)設有(you)供水(shui)(shui)管(帶浮閥),溢流(liu)管和污水(shui)(shui)管。 2。確定冷卻水(shui)系統的直徑 當(dang)冷(leng)卻(que)水裝置(zhi)裝有冷(leng)卻(que)塔(ta)和(he)冷(leng)卻(que)水泵時,冷(leng)卻(que)水管(guan)(guan)道的(de)(de)(de)(de)管(guan)(guan)徑(jing)(jing)可(ke)由(you)冷(leng)卻(que)塔(ta)進(jin)出(chu)口(kou)的(de)(de)(de)(de)管(guan)(guan)徑(jing)(jing)決定。當(dang)冷(leng)卻(que)塔(ta)用(yong)于(yu)多個(ge)單元時,每個(ge)單元的(de)(de)(de)(de)冷(leng)卻(que)水進(jin)、出(chu)管(guan)(guan)徑(jing)(jing)與該單元的(de)(de)(de)(de)冷(leng)卻(que)水接收器相同(tong)(tong)。冷(leng)卻(que)塔(ta)的(de)(de)(de)(de)進(jin)、出(chu)口(kou)管(guan)(guan)徑(jing)(jing)與冷(leng)卻(que)塔(ta)的(de)(de)(de)(de)進(jin)、出(chu)口(kou)管(guan)(guan)徑(jing)(jing)相同(tong)(tong)。 或參考以下清單選擇冷卻水(shui)管直徑:冷卻水(shui)管快(kuai)速計算表: 3 冷卻(que)水泵的選擇 (1)確定(ding)冷(leng)卻水泵流量 冷卻泵的流量(liang)為冷卻水供(gong)應(ying)裝(zhuang)置的1.1倍。 (2)冷(leng)卻水泵頭的測定(ding) 冷卻水泵的揚(yang)程(cheng)可按下列(lie)公式計算: H=1.1*(P1+Z+P2) 在公式(shi)中:p1冷水機組(zu)冷凝(ning)器水壓降,mh 2o,可從產品(pin)樣品(pin)中找到(dao); Z--冷卻(que)塔開口部分(fen)的(de)高(gao)度Z(或冷卻(que)水(shui)升降機的(de)凈高(gao)度),mH2O; p2-管道損失和配件部分損失之和,mh_2。 管道局部(bu)損失為5毫米波。每100米的(de)管道長度約為6mh 2o。如冷(leng)卻水(shui)系統(tong)的(de)供(gong)水(shui)及回水(shui)管長度為l(m),冷(leng)卻水(shui)泵升(sheng)降機(ji)的(de)估(gu)計值為: H = P1 + Z + 5 + L * 0.06mH2O中的(de)符號具有與上述相(xiang)同的(de)含義。 4 冷卻塔的(de)選擇 首先(xian),根據冷卻塔安裝位(wei)置的(de)(de)高度和周圍環境(jing)的(de)(de)噪聲要求,確定了冷卻塔的(de)(de)結構。 冷卻塔的冷卻水量是根據(ju)(ju)冰箱所需的冷卻水確定的,并(bing)根據(ju)(ju)室(shi)外(wai)空氣的濕(shi)球(qiu)溫度進行校(xiao)正(zheng)。 當設計條(tiao)件與冷(leng)卻塔制造商提供的條(tiao)件不同時,應校正產(chan)品樣品中給出的冷(leng)卻塔的熱性能(neng)曲線或(huo)數據。 確(que)定型號(hao)規(gui)格(ge)后,檢查所選(xuan)冷(leng)(leng)卻(que)(que)塔的(de)(de)結(jie)構尺寸(cun)是否適合現場安(an)裝條件。根據(ju)冷(leng)(leng)卻(que)(que)塔的(de)(de)運行(xing)(xing)重量,計(ji)(ji)算(suan)冷(leng)(leng)卻(que)(que)塔的(de)(de)運行(xing)(xing)重量,計(ji)(ji)算(suan)冷(leng)(leng)卻(que)(que)塔安(an)裝位置的(de)(de)樓層或屋頂(ding)結(jie)構的(de)(de)承載力,以確(que)保安(an)全。 凝結水管道系統的(de)設計(ji)步驟 在各種空調設備(bei)(一般是終端設備(bei))的運(yun)行過程中(zhong),空氣冷卻器的表(biao)面溫度通(tong)常低于空氣的露點溫度,因(yin)此表(biao)面會結(jie)露,產生的冷凝水必須安排在及(ji)時(shi)排干(gan)。 。 1。凝(ning)結(jie)水(shui)管設(she)計(ji)及布(bu)置要求 (1)冷凝水管(guan)應由(you)pvc塑料管(guan)或(huo)鍍(du)鋅(xin)鋼管(guan)制成。使(shi)用(yong)聚氯乙烯(xi)塑料管(guan)時,一般為保溫層;使(shi)用(yong)鍍(du)鋅(xin)鋼管(guan)時,應增(zeng)加隔(ge)熱(re)層。 (2)當空(kong)調器附(fu)近(jin)有下管(guan)或溝槽時,空(kong)調器設有水管(guan),以將冷凝(ning)水排放到下管(guan)或溝槽中(zhong)。 (3)當空(kong)調無法(fa)就(jiu)近排放(fang)時,空(kong)調冷凝管應(ying)通過冷凝管集中排放(fang)至下水道或溝渠。 (四(si))風扇線圈凝水盤排(pai)水管(guan)的斜率不得(de)小于0.01,其他水平(ping)(ping)分支保持(chi)水平(ping)(ping)方(fang)向的斜率不得(de)小于0.008,而(er)且不應該有水。 2 冷凝(ning)水管管徑的(de)確(que)定 直(zhi)接(jie)(jie)連接(jie)(jie)到空調水(shui)盤的冷(leng)凝水(shui)支管的直(zhi)徑(jing)應與(yu)接(jie)(jie)水(shui)盤的直(zhi)徑(jing)相同(tong),可以(yi)在產品樣品中(zhong)找到。 當需要凝(ning)結(jie)水管時(shi),應根據凝(ning)結(jie)水流(liu)量確定管道直徑。 在一(yi)般(ban)情況下,每(mei)千(qian)瓦的冷卻負荷每(mei)小時產生約0.4至0.8公斤的凝結(jie)水。 |